TY - GEN
T1 - On the Design and Analysis of Discrete-Time Plug- in Repetitive Controller with Three Different Internal Models
AU - Muslim, M. Aziz
AU - Kurniawan, Edi
AU - Rahmadwati,
AU - Edward, Ronald
N1 - Publisher Copyright:
© 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - This paper presents a design strategy for a discrete-time plug-in repetitive control (RC) method using three different internal models for a class of linear minimum phase systems. The internal models are the modified internal model, the odd-harmonics internal model, and the multi-periods internal model. The RC design includes an RC internal model, which generates periodic signals, and an RC compensator, which serves as a stabilizing controller. Simulations on a servo motor plant model are conducted to evaluate the performance of the designed RCs. The results demonstrate that the modified internal model offers an excellent tracking accuracy, the odd-harmonics internal model achieves the fastest convergence, and the multi-periods internal model excels in handling complex multi-frequency references. Overall, the results show that the plug-in RC method with the three different internal models demonstrates an optimal response, each with its own advantages and disadvantages.
AB - This paper presents a design strategy for a discrete-time plug-in repetitive control (RC) method using three different internal models for a class of linear minimum phase systems. The internal models are the modified internal model, the odd-harmonics internal model, and the multi-periods internal model. The RC design includes an RC internal model, which generates periodic signals, and an RC compensator, which serves as a stabilizing controller. Simulations on a servo motor plant model are conducted to evaluate the performance of the designed RCs. The results demonstrate that the modified internal model offers an excellent tracking accuracy, the odd-harmonics internal model achieves the fastest convergence, and the multi-periods internal model excels in handling complex multi-frequency references. Overall, the results show that the plug-in RC method with the three different internal models demonstrates an optimal response, each with its own advantages and disadvantages.
KW - compensator
KW - internal model
KW - linear system
KW - minimum phase
KW - plug-in repetitive controller
UR - https://www.scopus.com/pages/publications/85218027221
U2 - 10.1109/EECCIS62037.2024.10840060
DO - 10.1109/EECCIS62037.2024.10840060
M3 - Conference contribution
AN - SCOPUS:85218027221
T3 - Proceedings - 2024 12th Electrical Power, Electronics, Communications, Controls and Informatics Seminar, EECCIS 2024
SP - 162
EP - 164
BT - Proceedings - 2024 12th Electrical Power, Electronics, Communications, Controls and Informatics Seminar, EECCIS 2024
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 12th Electrical Power, Electronics, Communications, Controls and Informatics Seminar, EECCIS 2024
Y2 - 16 October 2024 through 18 October 2024
ER -