Skip to main navigation Skip to search Skip to main content

Inferior vena cava collapsibility index pre-induction is superior to caval aortic index pre-induction in predicting hypotension after induction of general anaesthesia

  • Wiwi Jaya*
  • , Ristiawan Muji Lakasono
  • , Alfons Octavian Sabandar
  • , Arie Zainul Fatoni
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Objective: The study aims to compare the pre-in-duction inferior vena cava collapsibility index (IVC-CI) and caval aortic index (CAo-I) as hy-potension after induction of general anaesthesia (GAIH) predictors. Design: This is an analytic observational study. Setting: This study was conducted in Dr. Saiful Anwar General Hospital. Patients and participant: This study was conducted on thirty-six patients undergoing general anaesthesia. Intervention: IVC-CI and CAo-I were measured before induction using ultrasound guide. Base-line blood pressure, mean arterial pressure (MAP), heart rate, maximum IVC diameter (dIVCmax), aortic diameter (dAo) were recorded before induction, then were repeated five minutes after induction. Patients received general anaesthesia induction using propofol 2 mg/kg. Analgesic using fentanyl 2 µg/kg and muscle relaxant using atracurium 0.5 mg/kg. Pa-tients received preoxygenation of 100% oxygen for 3-5 minutes. Result: MAP, heart rate, dIVCmax, dAo before and after induction were significantly different (p=0.000). Thirty patients (36.1%) experienced GAIH. There was no significant difference in age, gender, body mass index, physical status, and MAP pre-induction (p>0.05) between the hypotension and no-hypotension group, except for MAP induction (p=0.001). Pre-induction IVC-CI significantly correlated with hypoten-sion (p=0.024; r=0.375), but not in CAo-I (p>0.05; r=-0.100). The receiver operating characteristic test showed that IVC-CI had higher sensitivity (69.57%), specificity (69.23%), and accuracy (69.44%) than CAo-I, with cut-off value greater than 62.70% (confident interval 95%). Conclusion: Pre-induction IVC-CI is superior to CAo-I in predict hypotension after induction of general anaesthesia.

Original languageEnglish
Pages (from-to)247-256
Number of pages10
JournalCritical Care and Shock
Volume2021
Issue numberSeptember
Publication statusPublished - Sept 2021

Keywords

  • Caval aortic index
  • Hypotension
  • Inferior vena cava
  • Inferior vena cava collapsibility index
  • Mean arterial pressure

Fingerprint

Dive into the research topics of 'Inferior vena cava collapsibility index pre-induction is superior to caval aortic index pre-induction in predicting hypotension after induction of general anaesthesia'. Together they form a unique fingerprint.

Cite this