Finite element analysis of axial, radial and Halbach permanent magnet linear generators

  • Wijono*
  • , H. Arof
  • , W. N.L.W. Mahadi
  • , S. M. Said
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

Abstract

This paper presents a finite element analysis of permanent magnet linear generators. The machines can utilize axially magnetized permanent magnets (AMPM) only, radially magnetized permanent magnets (RMPM) only or a combination of both (Halbach) as the field sources. The study includes the analysis of the magnetic flux, flux linkage, induced voltage, cogging force and core-loss in the machines. The results provide comparative performances of tubular linear generators utilizing AMPM, RMPM and Halbach permanent magnet configuration along with the advantages and drawbacks of each type. It is found that the Halbach configuration provides a compromise between the axial and radial configuration, which results in a moderate induced voltage and overcomes the problem of high cogging force experienced in the axial configuration.

Original languageEnglish
Pages (from-to)2623-2629
Number of pages7
JournalInternational Review of Electrical Engineering
Volume5
Issue number6
Publication statusPublished - 2010

Keywords

  • Axial permanent magnet
  • Linear generator
  • Radial permanent magne
  • T Halbach configuration

Fingerprint

Dive into the research topics of 'Finite element analysis of axial, radial and Halbach permanent magnet linear generators'. Together they form a unique fingerprint.