Abstract
Renewable energy such as solar energy, waves and wind require batteries as a storage of electrical energy which still has constraints related to voltage, capacity, and energy efficiency. This experiment aims to determine the effect of electrode size on lead-acid dynamic and static battery capacity and energy efficiency. Dynamic and static single cell lead-acid batteries consist of three different electrode sizes, 13.5x7.5 cm2 (A1); 22.5x7.5 cm2 (A2) and 32.5x7.5 cm2 (A3) have been developed. Continuous and simultaneous charge-discharge test using turnigy accucell-6 50 w and chargemaster 2.02 software as graphic programming. Based on experiments, dynamic batteries perform better than static batteries with a difference in capacity of up to 48% and differences in energy efficiency up to 17%. The best performance is obtained on A3 dynamic batteries with an average capacity capacity of 10357 mAh and an average energy efficiency of 81%.
| Original language | English |
|---|---|
| Pages (from-to) | 2919-2925 |
| Number of pages | 7 |
| Journal | Telkomnika (Telecommunication Computing Electronics and Control) |
| Volume | 17 |
| Issue number | 6 |
| DOIs | |
| Publication status | Published - Dec 2019 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Charge-discharge
- Dynamic battery
- Efficiency
- Electrode size
- Renewable energy
Fingerprint
Dive into the research topics of 'Electrode size influence on static and dynamic single cell lead-acid battery'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver