Skip to main navigation Skip to search Skip to main content

Ductility of precast slab strengthened by external reinforcement

Research output: Contribution to journal › Conference article › peer-review

Abstract

The occurrence of structural failure in the building occurs due to changes function of a building, the age of the building, errors in the initial design, which were weak or did not meet the safety factor of a building. Reinforcement is needed to increase the strength and stability of the existing structure. The purpose of this study is to compare the strength of the slab before and after reinforcement in order to ascertain the impact of adding external reinforcement (ER) to the slab. A further goal of this research is to calculate the precast slabs' ductility following reinforcing. Seven slabs were utilised as specimens. Two slabs measuring 40 cm by 80 cm by 5 cm, three pieces measuring 40 cm by 100 cm by 5 cm, and two pieces measuring 40 cm by 120 cm by 5 cm are present. The experiment demonstrated that following strengthening, the slab's ultimate load increased but its ductility decreased.

Original languageEnglish
Article number060003
JournalAIP Conference Proceedings
Volume3043
Issue number1
DOIs
Publication statusPublished - 12 Dec 2024
Event1st International Conference on Sustainable Construction and Environment: Challenges on Sustainable Construction and its Impacts to the Environment, SCE 2022 - Virtual, Online, Indonesia
Duration: 3 Oct 2022 → 4 Oct 2022